jjm-logo
Jal Jeevan Mission
PHED Assam
emblem
GOVERNMENT OF ASSAM
Retrofilling of Bar Satra PWSS
BAR - SATRA, Darrang
Public Health Engineering Department
Mangaldoi Division
Latest Water Supplied
18 KL (29-08-2025)
Cumulative Water Supplied
15196.00 KL

Basic details of the scheme are enlisted here, for further information please contact concerned officer of division / sub division

About This Scheme

Name
Retrofilling of Bar Satra PWSS
Scheme ID
30245079
Division
Mangaldoi Division
District
Darrang
Block

Panchayat

PACHIM MANGALDOI (PART)

DAHI

Village

Habitation

BAR - SATRA

DHOKA PARA, KALITAPARA, BAR SATRA, METHANG PARA

Implementing Agency details of the scheme are enlisted here

About Scheme

Approved On
3rd SLSSC | (2021-22)
No. of FHTC
215
Total Cost
8501000.00
State Share
807500.00
Central Share
7268300.00
Handed Over On
2024-03-07 00:00:00

About Implementing Agency

Name of Agency
M/s J & D ENTERPRISE, Prop. Dipak Deka
Work Order Date
-
Name of Agency
SRI JOY CHANDRA SARMA
Work Order Date
2020-11-06

Jal Mitra & WUC Users details of the scheme are enlisted here

About Jal Mitra

Name
Dharmendra Kalita
Phone
6003193165

About WUC

WUC Name
Bar Satra WUC
President Name
JITENDRA NATH BARUAH
Secretary Name
BHADRESHWAR DEKA

About Section Officer

Name
Priyanka Deka
Phone
8638148917

Water Quality details of the scheme are enlisted here.

About Water Quality

Date of Testing
N/A
PH
N/A
TDS
N/A
Iron
N/A
Arsenic/Flouride
N/A
Residual Chlorine
N/A
Bacteriological Test
N/A

Component details of the scheme are enlisted here.

About Scheme Components

Asset Category
ESR
Component Name
Capacity
Ltr
Specification
Asset Category
Pump
Component Name
Centrifugal
Capacity
5.00 HP
Specification
Asset Category
Pump
Component Name
Submersible
Capacity
5.00 HP
Specification
Asset Category
Pump
Component Name
Centrifugal
Capacity
5.00 HP
Specification

Please click on button to view map.

Map

You need to login to evaluate a scheme.

Register

Login

Water Quality Test Report

Sample Tested Status

Total Samples Tested: 26

Chemical Testing Date: 7/26/2025 1:30:00 PM

Bacteriological Testing Date: 7/21/2025 2:27:00 PM

Water Quality Status: Safe

Remedial Action Status: --

Chemical Contamination Results

Parameter Unit Acceptable Limit Permissible Limit Value Range Status
Iron (As Fe) mg/l 1 No Relaxation 0.929

Safe :1

> 1 Safe

Bacteriological Contamination Results

Parameter Unit Acceptable Limit Permissible Limit Value Range Status
E. coli CFU/100 ml Shall not be detectable in any 100 ml sample No Relaxation 0.000

Safe :1

Shall not be detectable in any 100 ml sample Safe
Total coliform CFU/ 100 ml Shall not be detectable in any 100 ml sample No Relaxation 0.000

Safe :1

Shall not be detectable in any 100 ml sample Safe

Sample Testing Results

Date Contaminated Found Remedial Action Location Status Taken
26-07-2025 Chemical Not required Source Safe
25-07-2025 Chemical Not required Source Safe
21-07-2025 Chemical and bacteriological both Yes Source Unsafe
21-07-2025 Chemical and bacteriological both Not required Source Safe
18-07-2025 Chemical and bacteriological both Not required Source Safe
18-07-2025 Chemical and bacteriological both Yes Source Unsafe
16-07-2024 Chemical Not required Source Safe
06-06-2024 Chemical Yes Source Unsafe
04-06-2024 Bacteriological Not required Individual Household Safe
26-02-2024 Bacteriological Not required Source Safe
12-01-2024 Chemical and bacteriological both Yes Source Unsafe
28-08-2023 Chemical and bacteriological both Not required Source Safe
23-07-2023 Chemical and bacteriological both Not required Source Safe
23-07-2023 Chemical and bacteriological both Not required Source Safe
23-07-2023 Chemical and bacteriological both Not required Source Safe
23-07-2023 Chemical and bacteriological both Not required Source Safe
23-07-2023 Chemical and bacteriological both Not required Source Safe
19-05-2023 Chemical and bacteriological both Not required Source Safe
20-03-2023 Chemical and bacteriological both Not required Source Safe
20-03-2023 Chemical and bacteriological both Not required Source Safe
20-03-2023 Chemical and bacteriological both Not required Source Safe
20-03-2023 Chemical and bacteriological both Not required Source Safe
20-03-2023 Chemical and bacteriological both Not required Source Safe
20-03-2023 Chemical and bacteriological both Not required Source Safe
20-03-2023 Chemical and bacteriological both Not required Source Safe
21-12-2022 Chemical and bacteriological both Not required Source Safe

Nearest Laboratory

Lab Name: DLL Mangaldoi

Type: GOVT

Address: o/o Executive Engineer (PHE), Mangaldoi Div., P.O: Chapai, Dist: Mangaldoi, Assam Pin: 784529

Scheme Network Map

Submit your grievance through:

You can follow us on:

How satisfied are you with the scheme?