jjm-logo
Jal Jeevan Mission
PHED Assam
emblem
GOVERNMENT OF ASSAM
BEJARHOLA PWSS
Bajar Hola, Biswanath
Public Health Engineering Department
Tezpur Division Division
Latest Water Supplied
34 KL (28-05-2025)
Cumulative Water Supplied
4151.00 KL

Basic details of the scheme are enlisted here, for further information please contact concerned officer of division / sub division

About This Scheme

Name
BEJARHOLA PWSS
Scheme ID
30174541
Division
Tezpur Division
District
Biswanath
Block

Panchayat

CHATIA

SOOTEA NO.5

Village

Habitation

Bajar Hola

BAH-BARI, BEJORHOLA GAON NO.1

Implementing Agency details of the scheme are enlisted here

About Scheme

Approved On
1st SLSSC | (2022-23)
No. of FHTC
-
Total Cost
10643000.00
State Share
1011085.00
Central Share
9099765.00
Handed Over On
2024-10-04 00:00:00

About Implementing Agency

Name of Agency
UTTAM KUMAR HAZARIKA
Work Order Date
2023-06-13

Jal Mitra & WUC Users details of the scheme are enlisted here

About Jal Mitra

Name
NITU BARUAH
Phone
8486401840

About WUC

WUC Name
BEJARHOLA PWSS
President Name
Tankeswar Baruah
Secretary Name
Sanjay Lahon

About Section Officer

Name
Mrinal Phukan
Phone
7086127325

Water Quality details of the scheme are enlisted here.

About Water Quality

Date of Testing
N/A
PH
N/A
TDS
N/A
Iron
N/A
Arsenic/Flouride
N/A
Residual Chlorine
N/A
Bacteriological Test
N/A

Component details of the scheme are enlisted here.

About Scheme Components

Component Name
Submersible
Specification
Component Name
Openwell
Specification
Component Name
Openwell
Specification

Please click on button to view map.

Map

You need to login to evaluate a scheme.

Register

Login

Water Quality Test Report

Sample Tested Status

Total Samples Tested: 47

Chemical Testing Date: 2/6/2025 5:05:00 PM

Bacteriological Testing Date: 4/18/2024 2:10:00 PM

Water Quality Status: Safe

Remedial Action Status: --

Chemical Contamination Results

Parameter Unit Acceptable Limit Permissible Limit Value Range Status
Iron (As Fe) mg/l 1 No Relaxation 0.860

Safe :1

> 1 Safe
Fluoride (as F) mg/l 1 1.5 0.630

Safe :1

> 1.5 Safe
TDS mg/l 500 2000 80.000

Safe :1

> 2000 Safe
pH NA 6.5-8.5 No Relaxation 6.750

Safe :1

6.5-8.5 Safe
Turbidity NTU 1 5 2.800

Safe :1

> 5 Safe

Bacteriological Contamination Results

Parameter Unit Acceptable Limit Permissible Limit Value Range Status
Bacteriological (H2S test) NA Presence or Absence Presence or Absence 0.000

Safe :1

Presence or Absence Safe

Sample Testing Results

Date Contaminated Found Remedial Action Location Status Taken
06-02-2025 Chemical Not required Source Safe
06-02-2025 Chemical Not required Source Safe
06-02-2025 Chemical Not required Source Safe
06-02-2025 Chemical Not required Source Safe
06-02-2025 Chemical Not required Source Safe
30-01-2025 Chemical Not required Individual Household Safe
30-01-2025 Chemical Not required Individual Household Safe
14-11-2024 Chemical Not required Source Safe
20-09-2024 Chemical Not required Source Safe
20-09-2024 Chemical Not required Source Safe
20-09-2024 Chemical Not required Source Safe
20-09-2024 Chemical Not required Source Safe
20-09-2024 Chemical Not required Source Safe
20-09-2024 Chemical Not required Source Safe
31-05-2024 Chemical Not required Source Safe
31-05-2024 Chemical Not required Source Safe
31-05-2024 Chemical Not required Source Safe
18-04-2024 Chemical and bacteriological both Not required Source Safe
18-04-2024 Chemical and bacteriological both Not required Source Safe
18-04-2024 Chemical and bacteriological both Not required Source Safe
12-03-2024 Chemical and bacteriological both Not required Source Safe
12-03-2024 Chemical and bacteriological both Not required Source Safe
05-03-2024 Chemical and bacteriological both Not required Source Safe
05-03-2024 Chemical and bacteriological both Not required Source Safe
05-03-2024 Chemical and bacteriological both Not required Source Safe
05-03-2024 Chemical and bacteriological both Not required Source Safe
05-03-2024 Chemical and bacteriological both Not required Source Safe
05-03-2024 Chemical and bacteriological both Not required Source Safe
08-08-2023 Chemical and bacteriological both Not required Source Safe
08-08-2023 Chemical and bacteriological both Not required Source Safe
08-08-2023 Chemical and bacteriological both Not required Source Safe
08-08-2023 Chemical and bacteriological both Not required Source Safe
14-07-2023 Chemical and bacteriological both Not required Source Safe
13-07-2023 Chemical and bacteriological both Not required Source Safe
13-07-2023 Chemical and bacteriological both Not required Source Safe
16-05-2023 Chemical and bacteriological both Not required Source Safe
16-05-2023 Chemical and bacteriological both Not required Source Safe
16-05-2023 Chemical and bacteriological both Not required Source Safe
23-03-2023 Chemical and bacteriological both Not required Source Safe
23-03-2023 Chemical and bacteriological both Not required Source Safe
23-03-2023 Chemical and bacteriological both Not required Source Safe
23-03-2023 Chemical and bacteriological both Not required Source Safe
20-12-2022 Chemical and bacteriological both Not required Source Safe
20-12-2022 Chemical and bacteriological both Not required Source Safe
20-12-2022 Chemical and bacteriological both Not required Source Safe
20-12-2022 Chemical and bacteriological both Not required Source Safe
20-12-2022 Chemical and bacteriological both Not required Source Safe

Nearest Laboratory

Lab Name: DLL Biswanath Chariali

Type: GOVT

Address: O/O The Assistant Executive Engineer(PHE), Biswanath Chariali Sub Division, Near DC office, P.O: Biswanath, Assam, Pin: 784176

Scheme Network Map

You can follow us on:

How satisfied are you with the scheme?