jjm-logo
Jal Jeevan Mission
PHED Assam
emblem
GOVERNMENT OF ASSAM
Gobindpur PWSS
GARUMORAKOIBORTRA, Jorhat
Public Health Engineering Department
Jorhat Division Division
Latest Water Supplied
6 KL (12-02-2025)
Cumulative Water Supplied
494.00 KL

Basic details of the scheme are enlisted here, for further information please contact concerned officer of division / sub division

About This Scheme

Name
Gobindpur PWSS
Scheme ID
30179306
Division
Jorhat Division
District
Jorhat
Block

Panchayat

JORHAT NORTH WEST

MADHYA PARBATIA

Village

Habitation

GARUMORAKOIBORTRA

GUBINPUR

Implementing Agency details of the scheme are enlisted here

About Scheme

Approved On
2nd SLSSC | (2022-23)
No. of FHTC
30.00
Total Cost
5745000.00
State Share
545775.00
Central Share
4911975.00
Handed Over On
2024-10-28 00:00:00

About Implementing Agency

Name of Agency
Bharat Saikia
Work Order Date
-

Jal Mitra & WUC Users details of the scheme are enlisted here

About Jal Mitra

Name
Phone

About Section Officer

Name
RAJPRITOM BORA
Phone
7002363504

Water Quality details of the scheme are enlisted here.

About Water Quality

Date of Testing
N/A
PH
N/A
TDS
N/A
Iron
N/A
Arsenic/Flouride
N/A
Residual Chlorine
N/A
Bacteriological Test
N/A

Component details of the scheme are enlisted here.

About Scheme Components

Component Name
ugr
Specification
Component Name
ESR-Mild_Steel_GRP
Specification
Component Name
Submersible
Specification
Component Name
Centrifugal
Specification
Component Name
Openwell
Specification

Please click on button to view map.

Map

You need to login to evaluate a scheme.

Register

Login

Water Quality Test Report

Sample Tested Status

Total Samples Tested: 11

Chemical Testing Date: 6/27/2024 3:49:00 PM

Bacteriological Testing Date: 6/27/2024 3:49:00 PM

Water Quality Status: Safe

Remedial Action Status: --

Chemical Contamination Results

Parameter Unit Acceptable Limit Permissible Limit Value Range Status
Free residual Chlorine mg/l 0.2 1 0.000

Safe :1

> 1 Safe
Total Arsenic (As As) mg/l 0.01 No Relaxation 0.000

Safe :1

> 0.01 Safe
Iron (As Fe) mg/l 1 No Relaxation 0.270

Safe :1

> 1 Safe
TDS mg/l 500 2000 106.000

Safe :1

> 2000 Safe
pH NA 6.5-8.5 No Relaxation 7.190

Safe :1

6.5-8.5 Safe
Turbidity NTU 1 5 0.000

Safe :1

> 5 Safe

Bacteriological Contamination Results

Parameter Unit Acceptable Limit Permissible Limit Value Range Status
E. coli CFU/100 ml Shall not be detectable in any 100 ml sample No Relaxation 0.000

Safe :1

Shall not be detectable in any 100 ml sample Safe

Sample Testing Results

Date Contaminated Found Remedial Action Location Status Taken
27-06-2024 Chemical and bacteriological both Not required Source Safe
27-06-2024 Chemical and bacteriological both Not required Source Safe
27-06-2024 Chemical and bacteriological both Not required Source Safe
27-06-2024 Chemical and bacteriological both Not required Source Safe
27-06-2024 Chemical and bacteriological both Not required Source Safe
27-06-2024 Chemical and bacteriological both Not required Source Safe
27-06-2024 Chemical and bacteriological both Not required Source Safe
06-04-2024 Chemical and bacteriological both Not required Source Safe
06-04-2024 Chemical and bacteriological both Not required Source Safe
09-02-2024 Chemical and bacteriological both Not required Source Safe
09-11-2023 Chemical and bacteriological both Not required Source Safe

Nearest Laboratory

Lab Name: DLL Jorhat

Type: GOVT

Address: O/O The Ex. Engr (PHE) Jorhat Div. Na-Ali Jorhat Assam 785001

Scheme Network Map

You can follow us on:

How satisfied are you with the scheme?