jjm-logo
Jal Jeevan Mission
PHED Assam
emblem
GOVERNMENT OF ASSAM
Jaruagaon PWSS
JARUA GAON F.V., Kamrup
Public Health Engineering Department
Guwahati I Division Division
Latest Water Supplied
39 KL (24-04-2025)
Cumulative Water Supplied
114885.00 KL

Basic details of the scheme are enlisted here, for further information please contact concerned officer of division / sub division

About This Scheme

Name
Jaruagaon PWSS
Scheme ID
5441243
Division
Guwahati I Division
District
Kamrup
Block

Panchayat

Chaygaon

Dakhin Pantan

Village

Habitation

JARUA GAON F.V.

JARUAGAON, Jaruagaon Koimari

Implementing Agency details of the scheme are enlisted here

About Scheme

Approved On
1st SLSSC | (2020-21)
No. of FHTC
-
Total Cost
3700000.00
State Share
300000.00
Central Share
3100000.00
Handed Over On
2023-12-13 00:00:00

About Implementing Agency

Name of Agency
M/S ASHOK ENTERPRISE
Work Order Date
-

Jal Mitra & WUC Users details of the scheme are enlisted here

About Jal Mitra

Name
Mondeswar Rabha
Phone
9101043474

About WUC

WUC Name
WUC Jaruwagaon PWSS
President Name
Prasanna Rabha
Secretary Name
Rameswar Rabha

About Section Officer

Name
Himjyoti Kalita
Phone
9859471276

Water Quality details of the scheme are enlisted here.

About Water Quality

Date of Testing
N/A
PH
N/A
TDS
N/A
Iron
N/A
Arsenic/Flouride
N/A
Residual Chlorine
N/A
Bacteriological Test
N/A

Component details of the scheme are enlisted here.

About Scheme Components

Component Name
Submersible
Specification
Component Name
Centrifugal
Specification

Please click on button to view map.

Map

You need to login to evaluate a scheme.

Register

Login

Water Quality Test Report

Sample Tested Status

Total Samples Tested: 5

Chemical Testing Date: 11/5/2024 4:10:00 PM

Bacteriological Testing Date: 7/23/2023 4:00:00 PM

Water Quality Status: Safe

Remedial Action Status: --

Chemical Contamination Results

Parameter Unit Acceptable Limit Permissible Limit Value Range Status
Free residual Chlorine mg/l 0.2 1 0.000

Safe :1

> 1 Safe
Total Hardness (As CaCO3) mg/l 200 600 76.000

Safe :1

> 600 Safe
Chloride (as Cl) mg/l 250 1000 5.670

Safe :1

> 1000 Safe
TDS mg/l 500 2000 126.000

Safe :1

> 2000 Safe
pH NA 6.5-8.5 No Relaxation 7.500

Safe :1

6.5-8.5 Safe
Turbidity NTU 1 5 0.000

Safe :1

> 5 Safe

Bacteriological Contamination Results

Parameter Unit Acceptable Limit Permissible Limit Value Range Status
E. coli CFU/100 ml Shall not be detectable in any 100 ml sample No Relaxation 0.000

Safe :1

Shall not be detectable in any 100 ml sample Safe

Sample Testing Results

Date Contaminated Found Remedial Action Location Status Taken
05-11-2024 Chemical Not required Source Safe
28-06-2024 Chemical Not required Source Safe
14-06-2024 Chemical Not required Source Safe
23-07-2023 Chemical and bacteriological both Not required Source Safe
15-05-2023 Chemical and bacteriological both Not required Source Safe

Nearest Laboratory

Lab Name: DLL Kamrup

Type: GOVT

Address: o/o The Executive Engineer (PHE) Guwahati Div 1, Bamunimaidam, Guwahati 21

Scheme Network Map

You can follow us on:

How satisfied are you with the scheme?